User Tools

Site Tools


bf109e4n

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
bf109e4n [2013/03/20 16:18]
ATAG_Slipstream
bf109e4n [2013/03/21 16:18] (current)
Ivank [Rad Usage] more info IvanK
Line 48: Line 48:
  
   * Use Oil and Coolant Rads as required to control Coolant and Oil Temp.   * Use Oil and Coolant Rads as required to control Coolant and Oil Temp.
-  * Hal open is generally sufficient for most operations except at low IAS+  * Half open (Oil and Coolant)is generally sufficient for most operations except at low IAS or around 6000m
   * At high speed 1/3 rd Open is generally sufficient.   * At high speed 1/3 rd Open is generally sufficient.
-  * Slow speed is the worse situation. Sustained slow speed high power manoeuvring with < half rads should be avoided.+  * Slow speed is the worse situation. Sustained slow speed high power manoeuvring with < half rads should be avoided.... suggest Full open in this part of the envelope.
  
 ====LIMITATIONS==== ====LIMITATIONS====
bf109e4n.txt ยท Last modified: 2013/03/21 16:18 by Ivank